Outside FEMA flood zones
Candidate sites must sit in FEMA Zone X - outside the 100-year Special Flood Hazard Area and the 500-year floodplain. A flood determination is obtained for each site before it is accepted.
Insurability
A transformer, a cable reel, or a container of batteries is not ordinary warehouse stock. Sites are screened for low natural-catastrophe exposure and FEMA flood-zone status, and storage zones are specified to FM Global data sheet guidance.
Site selection
Candidate sites must sit in FEMA Zone X - outside the 100-year Special Flood Hazard Area and the 500-year floodplain. A flood determination is obtained for each site before it is accepted.
Sites are limited to regions without hurricane, storm-surge, or Tier 1 wind exposure. Roof and envelope condition is assessed against regional hail and monsoon-wind loading before a site is accepted.
Sites are screened for wildland-urban interface exposure and defensible space. We do not accept locations in mapped high or very-high fire-hazard severity zones.
Sites are screened for low seismic design category, keeping stored transformers, switchgear, and racked equipment away from ground-motion risk.
Buildings must be sprinklered, with municipal water supply and fire-department response verified and evaluated against FM DS 8-9 for the commodities to be stored.
Sites are screened for adjacent high-hazard occupancies and shared walls with unknown tenants, and must allow controlled site access.
Storage Standards
FM DS 5-4
Storage and maintenance of equipment-breakdown spare transformers: protection from physical damage, moisture, dirt and contaminants; suitable natural-hazard and fire exposure; inspection clearances; oil management; energized cabinet heaters; nitrogen blankets where configured; periodic inspections; and annual oil-quality analysis for liquid-filled units.
FM DS 7-112
The governing document for stored lithium-ion equipment. State of charge is central: higher SOC makes thermal runaway easier to initiate and increases fire intensity, so receipt, SOC limits, and storage arrangement are controlled accordingly.
FM DS 5-33
Applies where assembled or energized BESS equipment is held rather than transported components. FM continues to update 5-33 from its ongoing BESS research, and the BESS zone specification tracks those revisions.
FM DS 5-19
The governing document for HV and MV breakers and switchgear rated 600V and above. It covers protection, inspection, maintenance, and testing, on the basis that breaker failure comes mainly from poorly maintained mechanisms and insulation.
FM DS 8-9
The general warehouse fire-protection overlay for ordinary commodities, packaging, pallets, plastics, and racks. Where storage involves hazards beyond these commodity classes, the occupancy-specific sheet above governs - exactly as FM directs.
Read FM DS 8-9Segregated storage
Different equipment carries different risk. Each class is assigned its own zone, specified with the floor, protection, environment, and handling controls that class requires.
Asset preservation
Equipment is held to the manufacturer's preservation standard and released to the project with its records.
Each unit is stored to its manufacturer's receiving, storage, and installation instructions, obtained before the unit arrives.
Continuous temperature and humidity logs for the zone holding your equipment, available on request.
Gas-blanket pressure logs and annual oil analysis for liquid-filled units; results go in the unit file.
Documented condition on receipt (before unloading), at each inspection, and at release.
Controlled access, custody records, and site security from arrival to release.
A site and equipment dossier your broker and carrier can underwrite against.
Next step
Tell us what you need to store and where it is headed. We will walk through the zone, the applicable data sheets, and the documentation your carrier will want to see.